Sallen-Key Low-Pass Filter Designer
Single op-amp second-order Sallen-Key low-pass: given cutoff and Q, get standard R/C values, the real fc/Q, peaking and a Bode plot.
Key points
Sallen-Key Low-Pass Filter Designer: Single op-amp second-order Sallen-Key low-pass: given cutoff and Q, get standard R/C values, the real fc/Q, peaking and a Bode plot. Formula: f_c = 1/(2πR√(C1·C2)) | Q = ½·√(C1/C2) with R1 = R2 = R. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. In unity-gain Sallen-Key, Q depends only on the C1/C2 ratio, and R1 = R2 keeps offset and common-mode behaviour predictable. Use C0G or film for C1 — X7R voltage coefficient makes the cut-off drift with signal amplitude.
Inputs
f_c = 1/(2πR√(C1·C2)) | Q = ½·√(C1/C2) with R1 = R2 = RCalculation model (updates with parameters)
Bode plot (magnitude / phase, updates with parameters)
| R1 = R2 | 15.8 kΩ | |
| C1 (op-amp + input to ground) | 10 nF | |
| C2 (input to + input) | 10 nF | |
| Actual cut-off f_c | 1.007 kHz | target 1 kHz,偏差 0.73% |
| Actual Q | 0.500 | target 0.500 |
| Peaking | No peak (flattest) | |
| Minimum op-amp GBW | 50.37 kHz | Rule of thumb ≥100×f_c·Q, otherwise the roll-off slackens |
Engineering notes
- In unity-gain Sallen-Key, Q depends only on the C1/C2 ratio, and R1 = R2 keeps offset and common-mode behaviour predictable.
- Use C0G or film for C1 — X7R voltage coefficient makes the cut-off drift with signal amplitude.
FAQ
- What is Sallen-Key Low-Pass Filter Designer for?
- Single op-amp second-order Sallen-Key low-pass: given cutoff and Q, get standard R/C values, the real fc/Q, peaking and a Bode plot.
- What is the formula for Sallen-Key Low-Pass Filter Designer?
- Core formula: f_c = 1/(2πR√(C1·C2)) | Q = ½·√(C1/C2) with R1 = R2 = R. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using Sallen-Key Low-Pass Filter Designer?
- In unity-gain Sallen-Key, Q depends only on the C1/C2 ratio, and R1 = R2 keeps offset and common-mode behaviour predictable. Use C0G or film for C1 — X7R voltage coefficient makes the cut-off drift with signal amplitude.