Motor Sizing (Load Torque)

Favorite

Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check.

Key points

Motor Sizing (Load Torque): Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check. Formula: P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_N. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload. Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N.

Inputs

P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_N

Calculation model (updates with parameters)

T torque (N·m)n speed (r/min)0T_L = 50 N·m(constant)Constant torque: T constant · P ∝ n (conveyor / hoist)1440 r/minselected P_N = 11 kWMmotorn_M = 1440 r/mini=1.00transmissionT_M = 54.3 N·mloadT_L = 50 N·m · n_L = 1440 r/minService factor K and transmission efficiency η_t are already included
Load shaft power P_L7.539 kW
Required power (K×P_L/η_t)9.834 kW
Selected rated power P_N11 kW
Suggested rated speed / poles4 poles (rated ≈1440 r/min)
Rated torque T_N72.95 N·m
Overload check (peak ×1.0 vs λ=2.0)54 / 146 N·m ✓
Estimated rated current I_N21.85 A
matching drive capacity reference≥ 24 A VFD
drive scheme suggestionInduction motor + VFD; for wide-range low-speed running choose an inverter-duty motor (separate cooling)
⚠ Self-cooled motors lose cooling at low speed; below 30% rated speed long-term, use a separately driven fan or derate.

Engineering notes

  • Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload.
  • Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N.
  • DC machines don’t use power factor for current (I = P/(U·η)); size BLDC drives by bus current separately.

FAQ

What is Motor Sizing (Load Torque) for?
Size AC induction, DC, or brushed/brushless motors by load profile (constant torque / power / quadratic / shock): power, standard tier rounding, torque and overload check.
What is the formula for Motor Sizing (Load Torque)?
Core formula: P_L = T_L·n_L/9550 | P_N ≥ K·P_L/η_t | T_N = 9550·P_N/n_N | peak ≤ λ·T_N. The tool returns results instantly using this formula and the selected parameters.
What engineering notes should I keep in mind when using Motor Sizing (Load Torque)?
Four sizing steps: compute load power → apply the service factor → round to a standard power tier → check rated torque and peak overload. Select breakers / contactors / thermal relays by rated current; set the thermal relay to 1.05–1.1× I_N. DC machines don’t use power factor for current (I = P/(U·η)); size BLDC drives by bus current separately.