PCB Planar Transformer Designer
Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss.
Key points
PCB Planar Transformer Designer: Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss. Formula: N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D). Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common). Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current.
Inputs
N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D)Calculation model (updates with parameters)
| required ratio N2/N1 | 0.556 | Forward:Vout = k_v·Vin·n·Dmax |
| rounded turns N1 : N2 | 9 : 5 | actual ratio 0.556, error 0.00%(volt-second minimum N1 ≥ 6) |
| actual output voltage | 12.00 V | vs target 0.0% |
| Operating flux density Bpk | 92.3 mT | upper limit 150 mT · single-ended swing |
| Primary RMS current / suggested width | 0.61 A / 1.8 mm | Calculate 1.75mm · 3 layers (each 3 turns) |
| Secondary RMS current / suggested width | 1.01 A / 2.9 mm | Calculate 2.89mm · 3 layers (each 2 turns) |
| Total winding layers | 6 layers | Recommended P/S interleaving (e.g. P/S/P/S…) to reduce leakage |
| Winding copper loss estimate | 99.22 mW | Primary 50.86 mW + secondary 48.37 mW(R_pri 137.8 mΩ) |
Engineering notes
- Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common).
- Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current.
- Operating flux density is set by core loss (temperature rise), not saturation: use 0.1–0.15T at 100kHz, drop below 0.05T at 500kHz.
- Copper loss is a DC estimate (skin effect ignored): above 200kHz keep copper ≤ 2× skin depth (≈0.21mm at 100kHz; 1oz is fine).
FAQ
- What is PCB Planar Transformer Designer for?
- Planar transformer design: turns from the volt-second equation, rounded ratio, flux check, winding width/layers, and copper loss.
- What is the formula for PCB Planar Transformer Designer?
- Core formula: N1 ≥ Vin·D/(k_vs·f·B·Ae)|n = N2/N1 = Vout/(k_v·Vin·D). The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using PCB Planar Transformer Designer?
- Take Ae from the chosen core vendor’s datasheet (E22/E32/E38/E43/E58/E64 planar E cores are common). Interleaving P/S layers significantly lowers leakage (leakage ∝ layers²); parallel multiple secondary layers for high current. Operating flux density is set by core loss (temperature rise), not saturation: use 0.1–0.15T at 100kHz, drop below 0.05T at 500kHz. Copper loss is a DC estimate (skin effect ignored): above 200kHz keep copper ≤ 2× skin depth (≈0.21mm at 100kHz; 1oz is…