PCB Trace Current Capacity
Safe current from width, copper weight, and allowed temperature rise per IPC-2221, plus trace resistance / drop.
Key points
PCB Trace Current Capacity: Safe current from width, copper weight, and allowed temperature rise per IPC-2221, plus trace resistance / drop. Formula: I = k · ΔT^0.44 · A^0.725 (A in mil²). Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. For high current, first widen the trace / thicken copper / expose solder; add parallel via arrays on both sides. The formula is empirical; keep another 30%+ margin for sustained full load.
Inputs
I = k · ΔT^0.44 · A^0.725 (A in mil²)Calculation model (updates with parameters)
| Safe current capacity | 2.382 A | ΔT = 10°C(IPC-2221) |
| conductor cross-section | 54 mil² | |
| Trace resistance (50 mm) | 24.77 mΩ | DC value at 20°C |
| full-load drop / dissipation | 58.99 mV · 140.5 mW |
Engineering notes
- For high current, first widen the trace / thicken copper / expose solder; add parallel via arrays on both sides.
- The formula is empirical; keep another 30%+ margin for sustained full load.
FAQ
- What is PCB Trace Current Capacity for?
- Safe current from width, copper weight, and allowed temperature rise per IPC-2221, plus trace resistance / drop.
- What is the formula for PCB Trace Current Capacity?
- Core formula: I = k · ΔT^0.44 · A^0.725 (A in mil²). The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using PCB Trace Current Capacity?
- For high current, first widen the trace / thicken copper / expose solder; add parallel via arrays on both sides. The formula is empirical; keep another 30%+ margin for sustained full load.
Embed this calculator on your site / blog / intranet
Copy the snippet below into any HTML-capable page — visitors get the same live calculator, styling included.