Thermocouple mV ↔ Temperature (Cold-Junction Compensated)
Convert thermocouple EMF to temperature for K/J/T/E types with cold-junction compensation — forgetting this step is why a meter reading can be tens of degrees off.
Key points
Thermocouple mV ↔ Temperature (Cold-Junction Compensated): Convert thermocouple EMF to temperature for K/J/T/E types with cold-junction compensation — forgetting this step is why a meter reading can be tens of degrees off. Formula: E(T_hot) = E_meas + E(T_cold), then look up the table. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Uses ITS-90 reference points every 100°C with interpolation; error stays under 1°C from 0°C to the upper limit. Use the full tables for precision metrology. A common alternative is to measure the terminal temperature with a PT100/DS18B20 and use this tool — far more accurate than assuming 25°C.
Inputs
E(T_hot) = E_meas + E(T_cold), then look up the tableCalculation model (updates with parameters)
| Hot-junction temperature | 324.5 ℃ | |
| Compensated EMF E(T) | 13.2330 mV | 12.2090 + 1.0240 |
| Cold-junction compensation | 1.0240 mV | 冷端 25.0℃,≈等于 25.2 ℃ |
| Type / range | K 型 0~1000 ℃ |
Engineering notes
- Uses ITS-90 reference points every 100°C with interpolation; error stays under 1°C from 0°C to the upper limit. Use the full tables for precision metrology.
- A common alternative is to measure the terminal temperature with a PT100/DS18B20 and use this tool — far more accurate than assuming 25°C.
- Reversed polarity reads strongly negative; compensation cable must match the thermocouple type and polarity at the terminals.
FAQ
- What is Thermocouple mV ↔ Temperature (Cold-Junction Compensated) for?
- Convert thermocouple EMF to temperature for K/J/T/E types with cold-junction compensation — forgetting this step is why a meter reading can be tens of degrees off.
- What is the formula for Thermocouple mV ↔ Temperature (Cold-Junction Compensated)?
- Core formula: E(T_hot) = E_meas + E(T_cold), then look up the table. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using Thermocouple mV ↔ Temperature (Cold-Junction Compensated)?
- Uses ITS-90 reference points every 100°C with interpolation; error stays under 1°C from 0°C to the upper limit. Use the full tables for precision metrology. A common alternative is to measure the terminal temperature with a PT100/DS18B20 and use this tool — far more accurate than assuming 25°C. Reversed polarity reads strongly negative; compensation cable must match the thermocouple type and polarity at the terminals.