NTC Thermistor Temperature Calculator: Two-way B-equation conversion between temperature and resistance, plus reverse calculation from a pull-up + ADC reading, with sensitivity and ADC resolution. Formula: R = R25·e^{B(1/T − 1/T25)} | 1/T = 1/T25 + ln(R/R25)/B. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. The single-point B model is good to about ±1°C over 0–100°C; use the three-coefficient Steinhart-Hart model or a lookup table for precision work. Choosing a pull-up of 1/3 to 1× R25 puts the working temperature range on the steepest part of the divider curve.
Inputs
R = R25·e^{B(1/T − 1/T25)} | 1/T = 1/T25 + ln(R/R25)/BCalculation model (updates with parameters)
| Temperature | 25.00 ℃ | |
| NTC resistance | 10 kΩ | |
| Divider voltage Vout | 1.6500 V | NTC 在下、10.00kΩ 上拉 |
| 12-bit ADC code | 2048 | |
| Sensitivity | -4.44 %/℃ | Negative means resistance falls as temperature rises |
| Temperature per ADC code | 0.022 ℃/LSB | Approximately the smallest resolvable temperature step |
| Resistance ratio R/R25 | 1.0000 |
Engineering notes
- The single-point B model is good to about ±1°C over 0–100°C; use the three-coefficient Steinhart-Hart model or a lookup table for precision work.
- Choosing a pull-up of 1/3 to 1× R25 puts the working temperature range on the steepest part of the divider curve.
FAQ
- What is NTC Thermistor Temperature Calculator for?
- Two-way B-equation conversion between temperature and resistance, plus reverse calculation from a pull-up + ADC reading, with sensitivity and ADC resolution.
- What is the formula for NTC Thermistor Temperature Calculator?
- Core formula: R = R25·e^{B(1/T − 1/T25)} | 1/T = 1/T25 + ln(R/R25)/B. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using NTC Thermistor Temperature Calculator?
- The single-point B model is good to about ±1°C over 0–100°C; use the three-coefficient Steinhart-Hart model or a lookup table for precision work. Choosing a pull-up of 1/3 to 1× R25 puts the working temperature range on the steepest part of the divider curve.