Load Cell Output & Gain Calculator
From mV/V sensitivity and excitation, compute bridge output at full scale and at the current load, the gain needed and the ADC bits required — before wiring up an HX711 or ADS1232.
Key points
Load Cell Output & Gain Calculator: From mV/V sensitivity and excitation, compute bridge output at full scale and at the current load, the gain needed and the ADC bits required — before wiring up an HX711 or ADS1232. Formula: V_out = V_ex × sensitivity (mV/V) × load / capacity. Enter parameters on the DD-CAT IDE online tool page to get results instantly, with a calculation-model diagram that updates with the inputs. Only four-wire connection (excitation ± and signal ±) removes lead resistance; shield long cables and ground at one point. The HX711 uses a fixed gain of 128 with AVDD as reference — check its datasheet rather than reusing the gain suggested here.
Inputs
V_out = V_ex × sensitivity (mV/V) × load / capacityCalculation model (updates with parameters)
| Full-scale output | 10.000 mV | 5.00V × 2.00mV/V |
| Output at current load | 4.0000 mV | |
| Output per kg | 200.00 µV/kg | |
| Suggested gain | ×250.0 | 把满量程抬到Reference voltage 2.50V |
| Full scale after gain | 2.500 V | |
| ADC effective bits required | 14 bits | 分度 3000 份 × 4 ×Margin(理论下限 13.6 bits) |
Engineering notes
- Only four-wire connection (excitation ± and signal ±) removes lead resistance; shield long cables and ground at one point.
- The HX711 uses a fixed gain of 128 with AVDD as reference — check its datasheet rather than reusing the gain suggested here.
FAQ
- What is Load Cell Output & Gain Calculator for?
- From mV/V sensitivity and excitation, compute bridge output at full scale and at the current load, the gain needed and the ADC bits required — before wiring up an HX711 or ADS1232.
- What is the formula for Load Cell Output & Gain Calculator?
- Core formula: V_out = V_ex × sensitivity (mV/V) × load / capacity. The tool returns results instantly using this formula and the selected parameters.
- What engineering notes should I keep in mind when using Load Cell Output & Gain Calculator?
- Only four-wire connection (excitation ± and signal ±) removes lead resistance; shield long cables and ground at one point. The HX711 uses a fixed gain of 128 with AVDD as reference — check its datasheet rather than reusing the gain suggested here.